1,711 research outputs found

    Comparative study of imaging at 3.0 T versus 1.5 T of the knee

    Get PDF
    The objectives of the study were to compare MR imaging at 1.5 and 3.0 T in the same patients concerning image quality and visualization of cartilage pathology and to assess diagnostic performance using arthroscopy as a standard of reference. Twenty-six patients were identified retrospectively as having comparative 1.5 and 3.0 T MR studies of the knee within an average of 102 days. Standard protocols included T1-weighted and fat-saturated intermediate-weighted fast spin-echo sequences in three planes; sequence parameters had been adjusted to account for differences in relaxation at 3.0 T. Arthroscopy was performed in 19 patients. Four radiologists reviewed each study independently, scored image quality, and analyzed pathological findings. Sensitivities, specificities, and accuracies in diagnosing cartilage lesions were calculated in the 19 patients with arthroscopy, and differences between 1.5 and 3.0 T exams were compared using paired Student’s t tests with a significance threshold of p < 0.05. Each radiologist scored the 3.0 T studies higher than those obtained at 1.5 T in visualizing anatomical structures and abnormalities (p < 0.05). Using arthroscopy as a standard of reference, diagnosis of cartilage abnormalities was improved at 3.0 T with higher sensitivity (75.7% versus 70.6%), accuracy (88.2% versus 86.4%), and correct grading of cartilage lesions (51.3% versus 42.9%). Diagnostic confidence scores were higher at 3.0 than 1.5 T (p < 0.05) and signal-to-noise ratio at 3.0 T was approximately twofold higher than at 1.5 T. MRI at 3.0 T improved visualization of anatomical structures and improved diagnostic confidence compared to 1.5 T. This resulted in significantly better sensitivity and grading of cartilage lesions at the knee

    Target Cueing Provides Support for Target- and Resource-Based Models of the Attentional Blink

    Get PDF
    The attentional blink (AB) describes a time-based deficit in processing the second of two masked targets. The AB is attenuated if successive targets appear between the first and final target, or if a cueing target is positioned before the final target. Using various speeds of stimulus presentation, the current study employed successive targets and cueing targets to confirm and extend an understanding of target-target cueing in the AB. In Experiment 1, three targets were presented sequentially at rates of 30 msec/item or 90 msec/item. Successive targets presented at 90 msec improved performance compared with non-successive targets. However, accuracy was equivalently high for successive and non-successive targets presented at 30 msec/item, suggesting that–regardless of whether they occurred consecutively–those items fell within the temporally defined attentional window initiated by the first target. Using four different presentation speeds, Experiment 2 confirmed the time-based definition of the AB and the success of target-cueing at 30 msec/item. This experiment additionally revealed that cueing was most effective when resources were not devoted to the cue, thereby implicating capacity limitations in the AB. Across both experiments, a novel order-error measure suggested that errors tend to decrease with an increasing duration between the targets, but also revealed that certain stimulus conditions result in stable order accuracy. Overall, the results are best encapsulated by target-based and resource-sharing theories of the AB, which collectively value the contributions of capacity limitations and optimizing transient attention in time

    Medication administration errors for older people in long-term residential care

    Get PDF
    Background Older people in long-term residential care are at increased risk of medication errors. The purpose of this study was to evaluate a computerised barcode medication management system designed to improve drug administrations in residential and nursing homes, including comparison of error rates and staff awareness in both settings. Methods All medication administrations were recorded prospectively for 345 older residents in thirteen care homes during a 3-month period using the computerised system. Staff were surveyed to identify their awareness of administration errors prior to system introduction. Overall, 188,249 attempts to administer medication were analysed to determine the prevalence of potential medication administration errors (MAEs). Error classifications included attempts to administer medication at the wrong time, to the wrong person or discontinued medication. Analysis compared data at residential and nursing home level and care and nursing staff groups. Results Typically each resident was exposed to 206 medication administration episodes every month and received nine different drugs. Administration episodes were more numerous (p < 0.01) in nursing homes (226.7 per resident) than in residential homes (198.7). Prior to technology introduction, only 12% of staff administering drugs reported they were aware of administration errors being averted in their care home. Following technology introduction, 2,289 potential MAEs were recorded over three months. The most common MAE was attempting to give medication at the wrong time. On average each resident was exposed to 6.6 potential errors. In total, 90% of residents were exposed to at least one MAE with over half (52%) exposed to serious errors such as attempts to give medication to the wrong resident. MAEs rates were significantly lower (p < 0.01) in residential homes than nursing homes. The level of non-compliance with system alerts was low in both settings (0.075% of administrations) demonstrating virtually complete error avoidance. Conclusion Potentially inappropriate administration of medication is a serious problem in long-term residential care. A computerised barcode system can accurately and automatically detect inappropriate attempts to administer drugs to residents. This tool can reliably be used by care staff as well as nurses to improve quality of care and patient safety

    Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint

    Get PDF
    The objectives of the study were to optimize three cartilage-dedicated sequences for in vivo knee imaging at 7.0 T ultra-high-field (UHF) magnetic resonance imaging (MRI) and to compare imaging performance and diagnostic confidence concerning osteoarthritis (OA)-induced changes at 7.0 and 3.0 T MRI. Optimized MRI sequences for cartilage imaging at 3.0 T were tailored for 7.0 T: an intermediate-weighted fast spin-echo (IM-w FSE), a fast imaging employing steady-state acquisition (FIESTA) and a T1-weighted 3D high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) sequence. Three healthy subjects and seven patients with mild OA were examined. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diagnostic confidence in assessing cartilage abnormalities, and image quality were determined. Abnormalities were assessed with the whole organ magnetic resonance imaging score (WORMS). Focal cartilage lesions and bone marrow edema pattern (BMEP) were also quantified. At 7.0 T, SNR was increased (p &lt; 0.05) for all sequences. For the IM-w FSE sequence, limitations with the specific absorption rate (SAR) required modifications of the scan parameters yielding an incomplete coverage of the knee joint, extensive artifacts, and a less effective fat saturation. CNR and image quality were increased (p &lt; 0.05) for SPGR and FIESTA and decreased for IM-w FSE. Diagnostic confidence for cartilage lesions was highest (p &lt; 0.05) for FIESTA at 7.0 T. Evaluation of BMEP was decreased (p &lt; 0.05) at 7.0 T due to limited performance of IM-w FSE. Gradient echo-based pulse sequences like SPGR and FIESTA are well suited for imaging at UHF which may improve early detection of cartilage lesions. However, UHF IM-w FSE sequences are less feasible for clinical use

    Quail Genomics: a knowledgebase for Northern bobwhite

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Quail Genomics knowledgebase (<url>http://www.quailgenomics.info</url>) has been initiated to share and develop functional genomic data for Northern bobwhite (<it>Colinus virginianus</it>). This web-based platform has been designed to allow researchers to perform analysis and curate genomic information for this non-model species that has little supporting information in GenBank.</p> <p>Description</p> <p>A multi-tissue, normalized cDNA library generated for Northern bobwhite was sequenced using 454 Life Sciences next generation sequencing. The Quail Genomics knowledgebase represents the 478,142 raw ESTs generated from the sequencing effort in addition to assembled nucleotide and protein sequences including 21,980 unigenes annotated with meta-data. A normalized MySQL relational database was established to provide comprehensive search parameters where meta-data can be retrieved using functional and structural information annotation such as gene name, pathways and protein domain. Additionally, blast hit cutoff levels and microarray expression data are available for batch searches. A Gene Ontology (GO) browser from Amigo is locally hosted providing 8,825 unigenes that are putative orthologs to chicken genes. In an effort to address over abundance of Northern bobwhite unigenes (71,384) caused by non-overlapping contigs and singletons, we have built a pipeline that generates scaffolds/supercontigs by aligning partial sequence fragments against the indexed protein database of chicken to build longer sequences that can be visualized in a web browser. </p> <p>Conclusion</p> <p>Our effort provides a central repository for storage and a platform for functional interrogation of the Northern bobwhite sequences providing comprehensive GO annotations, meta-data and a scaffold building pipeline. The Quail Genomics knowledgebase will be integrated with Japanese quail (<it>Coturnix coturnix</it>) data in future builds and incorporate a broader platform for these avian species. </p

    Understanding the Role of Molecular Diffusion and Catalytic Selectivity in Liquid-Phase Beckmann Rearrangement

    Get PDF
    Understanding the role of diffusion in catalysis is essential in the design of highly active, selective, and stable industrial heterogeneous catalysts. By using a combination of advanced in situ spectroscopic characterization tools, particularly quasi-elastic and inelastic neutron scattering, we outline the crucial differences in diffusion modes and molecular interactions of active sites within solid-acid catalysts. This, coupled with 2D solid-state NMR and probe-based FTIR spectroscopy, reveals the nature of the active site in our SAPO-37 catalyst and affords detailed information on the evolution of solid-acid catalysts that can operate at temperatures as low as 130 °C, for the Beckmann rearrangement of cyclohexanone oxime to ε-caprolactam (precursor for Nylon-6). The versatility of this approach leads to structure−property correlations that contrast the dynamics of the diffusion process in the different materials studied. Our results illustrate the power of these techniques in unravelling the interplay between active site and molecular diffusion in single-site heterogeneous catalysts, which can play a vital role in designing low-temperature, sustainable catalytic processes

    Genetic counselling for psychiatric disorders: accounts of psychiatric health professionals in the United Kingdom

    Get PDF
    Genetic counselling is not routinely offered for psychiatric disorders in the United Kingdom through NHS regional clinical genetics departments. However, recent genomic advances, confirming a genetic contribution to mental illness, are anticipated to increase demand for psychiatric genetic counselling. This is the first study of its kind to employ qualitative methods of research to explore accounts of psychiatric health professionals regarding the prospects for genetic counselling services within clinical psychiatry in the UK. Data were collected from 32 questionnaire participants, and 9 subsequent interviewees. Data analysis revealed that although participants had not encountered patients explicitly demanding psychiatric genetic counselling, psychiatric health professionals believe that such a service would be useful and desirable. Genomic advances may have significant implications for genetic counselling in clinical psychiatry even if these discoveries do not lead to genetic testing. Psychiatric health professionals describe clinical genetics as a skilled profession capable of combining complex risk communication with much needed psychosocial support. However, participants noted barriers to the implementation of psychiatric genetic counselling services including, but not limited to, the complexities of uncertainty in psychiatric diagnoses, patient engagement and ethical concerns regarding limited capacity

    Combined aerobic and resistance exercise training decreases peripheral but not central artery wall thickness in subjects with type 2 diabetes

    Get PDF
    Objective Little is known about the impact of exercise training on conduit artery wall thickness in type 2 diabetes. We examined the local and systemic impact of exercise training on superficial femoral (SFA), brachial (BA), and carotid artery (CA) wall thickness in type 2 diabetes patients and controls. Methods Twenty patients with type 2 diabetes and 10 age- and sex-matched controls performed an 8-week training study involving lower limb-based combined aerobic and resistance exercise training. We examined the SFA to study the local effect of exercise, and also the systemic impact of lower limb-based exercise training on peripheral (i.e. BA) and central (i.e. CA) arteries. Wall thickness (WT), diameter and wall:lumen(W:L)-ratios were examined using automated edge detection of ultrasound images. Results Exercise training did not alter SFA or CA diameter in type 2 diabetes or controls (all P > 0.05). BA diameter was increased after training in type 2 diabetes, but not in controls. Exercise training decreased WT and W:L ratio in the SFA and BA, but not in CA in type 2 diabetes. Training did not alter WT or W:L ratio in controls (P > 0.05). Conclusion Lower limb-dominant exercise training causes remodelling of peripheral arteries, supplying active and inactive vascular beds, but not central arteries in type 2 diabetes

    Radio emission from Supernova Remnants

    Get PDF
    The explosion of a supernova releases almost instantaneously about 10^51 ergs of mechanic energy, changing irreversibly the physical and chemical properties of large regions in the galaxies. The stellar ejecta, the nebula resulting from the powerful shock waves, and sometimes a compact stellar remnant, constitute a supernova remnant (SNR). They can radiate their energy across the whole electromagnetic spectrum, but the great majority are radio sources. Almost 70 years after the first detection of radio emission coming from a SNR, great progress has been achieved in the comprehension of their physical characteristics and evolution. We review the present knowledge of different aspects of radio remnants, focusing on sources of the Milky Way and the Magellanic Clouds, where the SNRs can be spatially resolved. We present a brief overview of theoretical background, analyze morphology and polarization properties, and review and critical discuss different methods applied to determine the radio spectrum and distances. The consequences of the interaction between the SNR shocks and the surrounding medium are examined, including the question of whether SNRs can trigger the formation of new stars. Cases of multispectral comparison are presented. A section is devoted to reviewing recent results of radio SNRs in the Magellanic Clouds, with particular emphasis on the radio properties of SN 1987A, an ideal laboratory to investigate dynamical evolution of an SNR in near real time. The review concludes with a summary of issues on radio SNRs that deserve further study, and analyzing the prospects for future research with the latest generation radio telescopes.Comment: Revised version. 48 pages, 15 figure

    Ultrasound-evoked immediate early gene expression in the brainstem of the Chinese torrent frog, Odorrana tormota

    Get PDF
    The concave-eared torrent frog, Odorrana tormota, has evolved the extraordinary ability to communicate ultrasonically (i.e., using frequencies > 20 kHz), and electrophysiological experiments have demonstrated that neurons in the frog’s midbrain (torus semicircularis) respond to frequencies up to 34 kHz. However, at this time, it is unclear which region(s) of the torus and what other brainstem nuclei are involved in the detection of ultrasound. To gain insight into the anatomical substrate of ultrasound detection, we mapped expression of the activity-dependent gene, egr-1, in the brain in response to a full-spectrum mating call, a filtered, ultrasound-only call, and no sound. We found that the ultrasound-only call elicited egr-1 expression in the superior olivary and principal nucleus of the torus semicircularis. In sampled areas of the principal nucleus, the ultrasound-only call tended to evoke higher egr-1 expression than the full-spectrum call and, in the center of the nucleus, induced significantly higher egr-1 levels than the no-sound control. In the superior olivary nucleus, the full-spectrum and ultrasound-only calls evoked similar levels of expression that were significantly greater than the control, and egr-1 induction in the laminar nucleus showed no evidence of acoustic modulation. These data suggest that the sampled areas of the principal nucleus are among the regions sensitive to ultrasound in this species
    corecore